A calibration register template that the finder reads as it stands: the twenty-eight columns below as a CSV that opens in Excel, with four invented rows. Fill it in, paste it back, and every instrument comes back with its due date worked out and the findings raised. The register you already keep works too: a column the finder cannot find is reported as not recorded, never guessed.

Download the template (CSV)See the specimen run

Columns the finder reads

header names are matched loosely
ColumnWhat goes in itNeeded
Asset IDthe number on the instrument and its labelrequired
Typewhat it is: caliper, micrometer, torque wrench, pressure gauge, analytical balancerequired
Descriptionrange, size, modeladvised
Locationwhere it livesadvised
Ownerdepartment or person who answers for itadvised
Control typecalibration, verification, intermediate check, qualification or mapping: the wording of the due date follows itoptional
Last calibrationthe date of the last calibration or verification; ISO dates always read, set day first or month first for the othersrequired
Interval12 months, 6 mo, quarterly, 90 days, 2 years, biennial, or before each userequired
Due dateoptional: the finder works it out and shows where yours disagreesoptional
Cal byin house or externalstrongly advised
Calibration providerthe external lab or provider; shown, not evaluatedoptional
Lab accredited to ISO/IEC 17025yes, no or unknownfor external labs
Accreditation bodyshown, not evaluatedoptional
Scope referencethe accreditation scope the service sits in; shown, not evaluatedoptional
Certificate numberthe calibration certificate or record referencestrongly advised
Traceable to a national standardyes or noadvised
Reference standardthe reference an in-house calibration is done against; shown, not evaluatedoptional
Uncertaintyas the certificate states it; shown, never worked outoptional
As foundin tolerance or out of tolerance at the last calibrationstrongly advised
Adjustedyes or nooptional
Used for product acceptanceyes or nostrongly advised
Used ona process or product family, never a part numberoptional
Statusin service, out of service, reference only, calibration not required, lost, quarantined, retiredstrongly advised
Rationalewhy calibration is not requiredwith calibration not required
Approverwho agreed itwith calibration not required
Procedurethe procedure an in-house calibration followsfor in-house
Impact assessmentyes, no, or a reference such as an NCR numberafter an out-of-tolerance reading
Notesa short label; a cell over 300 characters is removedoptional

A first line for the register

standards: IATF 16949, ISO 9001 | audit date: 2026-11-09 | warning window: 30 days | date format: day first | as at: 2026-09-28

The standards set which clauses are cited and whether an external lab without accreditation is a finding or a question; the audit date and warning window set what is due soon; the as-at date is the date every due date is read against.

The four rows in the CSV

invented
Asset IDTypeLast calibrationIntervalStatus
G-001micrometer2026-03-1012 monthsin service
G-002torque wrench2026-06-016 monthsin service
G-003height gauge2025-10-1512 monthsin service
G-004surface platecalibration not required

Fill it in, paste it back: the calibration schedule comes back as a recall sheet, overdue first, and the CSV export adds an action owner and an action due column for each finding.